English Print Books Some Technical Points To Pay Attention To When Operating A Flat Scanner
Apr 21, 2023
Leave a message
English Print Books Some technical points to pay attention to when operating a flat scanner
With the improvement of plane scanner technology and its advantages in price, more and more users are using plane scanner in color desktop system. In order to meet the needs of the majority of users, in recent years, according to different grades, specifications and uses, plane scanners are divided into professional type and ordinary type two categories. Understanding the functions of the plane scanner can enable the operator to scan better quality images smoothly. The following plane scanner's main functions and operation points to talk about a little superficial view.
First, the selection of scanning mode
The scanning mode of plane scanner can be divided into automatic and manual. These two different scanning methods will have different effects on image quality.
1. Automatic scanning
Automatic scanning refers to the "AI" function, also known as the "fool" function. When the automatic scanning mode is selected, the scanner will conduct the initial scanning of the image, identify the pixel distribution and the highest density and the lowest density, so as to adjust the output signal of R, G and B after processing by the computer, and then conduct the formal scanning. Therefore, when scanning under this state is selected, attention should be paid to not select the content outside the picture into the scanning format when setting the scanning range. If the white edge, black edge or cover plate outside the picture is also selected within the set scanning range, the picture has included the information content that does not belong to the original manuscript. The automatic scanning software will make incorrect judgments on the information of the original manuscript, resulting in the main characteristics of the automatic scanning software of the scanned image is to automatically find the black and white fields and calculate the contrast on the premise of the correct neutral gray balance setting, so that the image can be copied and restored after scanning. So in the use of automatic scanning function, we should pay attention to whether the original manuscript is biased color, contrast is appropriate. Otherwise, the image quality will not be as good as it should be when the automatic feature is used to scan the image.
2. Manual scanning
In most cases, we need to use manual scanning. This method can effectively adjust the color bias, contrast and curve state of the manuscript, so that it can better show the level of a part of the manuscript. When a manual status scan is performed, a series of dialogs will appear that need to be set at each scan. Common scanners generally have the following Settings.
(1) Setting of highlights and darks
The setting of highlight and dark tone is also known as the setting of white field and black field. According to the different scanning software set up by the scanner, it can be roughly divided into the following three situations: black and white field calibration in the state of printing dot C, M, Y and K; The brightness level in the form of RGB sets the black field and the white field. Generally, the white field is set between 170 and 255, and the black field is set between 0 and 85. It appears in the form of original density. When setting, it scales the white field and the black field with the lowest and highest density of the original manuscript. Some scanners use the form of light tone and dark tone to indicate by digital level.
In the Settings of the above highlights and darks, the RGB form of printing dot is used for calibration. The color bias and contrast of the original manuscript can be greatly adjusted; When scanning with maximum and minimum density, the contrast will be adjusted on the basis of ensuring that the original tone is restored.
(2) Setting of Curve and gamma Camma values
The state of Curve and the setting of gamma curve will be related to the hierarchical performance after image scanning. Due to the different density contrast of the transmission manuscript, reflected manuscript and printed matter, all levels of the original manuscript should be copied on the printed matter, so that the bright tone, the middle tone and the dark tone can be fully displayed on the paper, and the curve state needs to be adjusted for a variety of different replication conditions. Most software of plane scanner can not only adjust the curve as a whole, but also adjust individual curve states in the form of ruler R, G and B. In this way, we can repair the neutral gray balance of the ink, but also can deal with the overall color of the manuscript. [next]
Second, the scanning Settings of the printed manuscript
In the top setting is generally divided into 85lpi(newsprint), 133 lpi(magazine), 150 lpi(general) and 175 lpi(sample) four tops. Because the printing is composed of dot, and then copy is carried out on the basis of some original dot, at this time will produce interference graphics. For the printing of the image with interference graphics, it will form an irregular pattern on the tone of the unit area, so that it will produce a lattice pattern on the printed matter, commonly known as "moire". This item is set for a flat scanner. Actually is to scan the focal length of adjustment, so that the scanner can not print the dot distinguish out. Therefore, when this setting is carried out, the image sharpness will be affected to some extent. The adjustment amplitude of 85 lpi with the thickest dot is the largest, the image is correspondingly fuzzy, and the adjustment amplitude of 175 lpi with the thinnest dot is the smallest. Therefore, when it is not possible to determine the printing network cable of the original print, in order to maintain the clarity of the image as far as possible, you should start scanning by selecting a finer network cable setting until no "moire" appears.
Three, sharpness setting
It is important to point out here that sharpness does not equal sharpness. The sharpness, though, improves clarity in terms of visual effects. But on the other hand, excessive sharpness will make the image become rough, especially when the original silver salt particles thicker photos and prints should be paid more attention to. In a flat scanner. The sharpness of the image depends on the optical resolution of the scanner; Sharpness creates a white edge and a black edge in the region between high density and low density. To improve the clarity of the visual effect. For such a computer-generated line, three factors will determine the depth (Amount), range (Radius), and Threshold (Threshold). Some scanning software classifies sharpness into light, medium and emphasis. In general, you can choose slightly higher sharpness for reverse films, medium sharpness for photos, and slight sharpness for prints. In addition, for the original presentation content, such as still life, landscape class sharpness can be slightly higher. And characters can choose a lower tax Settings.
Four, image resolution setting
The setting of the image resolution shall depend on the network cable of the final output film. In general, you should set the image resolution to twice the required output network cable. For example: output 150 lpi, the image resolution should be 300 dpi; Output 175 lpi, image resolution of course correspondingly improved. The higher you set the resolution. The corresponding level of reflection may be better, but the amount of files will also increase, which will greatly reduce the speed of file scanning, transfer and production. On the contrary, too low resolution image will greatly reduce the content contained, although the file amount is reduced, file transmission, production speed is improved, but the output of the film in the image part of the image resolution can not match the output precision of the film and Mosaic phenomenon.
In line scanning, such as the normal setting of image resolution. There will be a lot of zigzag in line turns and slashes. It brings a lot of trouble to the post production. When the resolution of the image is increased to 1200 dpi, the sawtooth phenomenon will be greatly reduced. Of course, when improving the image resolution, the scanning speed will be reduced due to the increase in the number of files. However, after scanning, in order not to affect the transmission and production speed of the file, you can reduce the resolution of the file to the normal state.
Each of the planar scanner speak is not the same, but their basic content is largely consistent operation. Operators need to have a full understanding of the main operation function, adjustment range and performance ability, at the same time need to have an understanding of the printing process and knowledge, familiar with the color law of C, M, Y, K. In this way, the image quality can be better achieved to a satisfactory degree.